Alarm Name
Alarm
Sub
Number
Code
4508
SPECIFIED ERROR
0
(COORDINATE)
1
2
3
Meaning
Cause
other
The specified coordinate
Setting error
system does not exist.
other
Designation error of the
Setting error
master tool coordinate
system. This coordinate
system cannot be used.
other
Designation error of the tool
Setting error
coordinate system. This
coordinate system cannot be
used.
other
Designation error of the
Setting error
direction of travel coordinate
system (for a shared function).
This coordinate system
cannot be used.
other
Remedy
If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
(1)Check the following settings.
Check the settings for the coordinate system which can be used.
If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
(1)Check the following settings.
Check the settings for the coordinate system which can be used.
If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
(1)Check the following settings.
Check the settings for the coordinate system which can be used.
If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
(1)Check the following settings.
Check the settings for the coordinate system which can be used.
If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).