Alarm Name
Alarm
Sub
Number
Code
4713
EXT 24V POWER
ERR (EW-BOARD)
4714
18V LINE BROKEN
(EW-BOARD)
4715
CIP MESSAGE
1
SERVER FUNC
ERROR
2
3
4
5
Meaning
Cause
other
Connection failure
Unit failure
other
YEW01 board failure
other
Failed in the generation of the
Software operation error
CIP server task.
occurred
Failed in the ID take of the CIP
Software operation error
server task.
occurred
Failed in the generation of the
Software operation error
class entry table.
occurred
Library initialize error.
Software operation error
occurred
Failed in the generation of the
Software operation error
access process.
occurred
Remedy
If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
Check if the 24V line that is input for YEW board is correctly wired.
Replace the unit that supplies with the external 24V power.
If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
Replace the YEW board of the corresponding station.
If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance
mode, and then contact your Yaskawa representative about
occurrence status (operating procedure).
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance
mode, and then contact your Yaskawa representative about
occurrence status (operating procedure).
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance
mode, and then contact your Yaskawa representative about
occurrence status (operating procedure).
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance
mode, and then contact your Yaskawa representative about
occurrence status (operating procedure).
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance
mode, and then contact your Yaskawa representative about
occurrence status (operating procedure).