YASKAWA DX200 Maintenance Manual page 1039

Hide thumbs Also See for DX200:
Table of Contents

Advertisement

Alarm Name
Alarm
Sub
Number
Code
23
24
25
4598
PAINTOUT ERROR
1
4599
SERVO COMMAND
ERROR
4601
UNDEFINED GUN
COND FILE
4603
WIRE STICKING
Meaning
Cause
Incorrect designation of the
Software operation error
occupation control group for
occurred
welding path shift function.
The inverse shift data for
Software operation error
welding path shift function
occurred
could not correctly be
calculated.
The inverse shift data for
Software operation error
welding path shift function
occurred
could not correctly be added.
The parameter setting for the
Setting error
universal input group number
is incorrect.
other
An attempt was made to issue
Software operation error
the command while the servo
occurred
control processing has not
completed.
Sub Code: Servo CPU bit
number
Sub Code: Gun condition file
Setting error
number
other
Sub Code: Welder number
Setting error
Remedy
(1)Reset the alarm, select [UTILITY]-[ARC SHIFT CANCEL], and then
try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance
mode, and then contact your Yaskawa representative about
occurrence status (operating procedure).
(1)Reset the alarm, select [UTILITY]-[ARC SHIFT CANCEL], and then
try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance
mode, and then contact your Yaskawa representative about
occurrence status (operating procedure).
(1)Reset the alarm, select [UTILITY]-[ARC SHIFT CANCEL], and then
try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance
mode, and then contact your Yaskawa representative about
occurrence status (operating procedure).
(1)Check the following settings.
Check the settings for the AxP011.
If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance
mode, and then contact your Yaskawa representative about
occurrence status (operating procedure).
(1)Check the following settings.
Complete the gun condition file setting.
If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
(1)Check the following settings.
Remove the cause of wire stick.

Hide quick links: