Alarm Name
Alarm
Sub
Number
Code
4591
SPEED CTRL MODE
SET ERR (SERVO)
4592
SPEED CTRL MODE
CANCEL ERR(SV)
4593
SVHAND CTRL
MODE SET ERR
(SERVO)
4594
SVHND CTRL MODE
CANCEL ERR (SV)
4595
CAN'T DO FIXED
1
FORM CUT MOTION
Meaning
Cause
Software operation error
occurred
Software operation error
occurred
Software operation error
occurred
Software operation error
occurred
The setting for radius is
Setting error
incorrect.
(1) For a circle, it is incorrectly
set as: radius <= 0, radius <
minimum radius value, or
radius > maximum radius
value.
(2) For an ellipse, it is
incorrectly set as: radius <= 0,
radius < minimum radius
value/2, or radius > (maximum
radius/2 - width/2).
other
Remedy
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance
mode, and then contact your Yaskawa representative about
occurrence status (operating procedure).
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance
mode, and then contact your Yaskawa representative about
occurrence status (operating procedure).
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance
mode, and then contact your Yaskawa representative about
occurrence status (operating procedure).
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance
mode, and then contact your Yaskawa representative about
occurrence status (operating procedure).
(1)Check the following settings.
∙
Setting of the radius data
If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).