YASKAWA DX200 Maintenance Manual page 1066

Hide thumbs Also See for DX200:
Table of Contents

Advertisement

Alarm Name
Alarm
Sub
Number
Code
4670
INSUFFICIENT NUM
OF SAMPLE DATA
4671
SAMPLE BUFFER
OVER FLOW
4672
BASIC SPEED
UNREACHED
4673
MAX TRQ
UNDETECTED
4674
SETE ERROR
1
Meaning
Cause
Setting error
other
Sub Code: Signifies the axis
Setting error
in which the alarm occurred
other
Sub Code: Signifies the axis
Setting error
in which the alarm occurred
other
Sub Code: Signifies the axis
Setting error
in which the alarm occurred
other
Sub Code: Signifies the axis
Setting error
in which the alarm occurred
other
An attempt was made to set
Setting error
tool for base/station-axis
position-type variable.
other
Remedy
(1)Reset the alarm.
(2)Check the following settings.
?Check torque value
If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
(1)Reset the alarm.
(2)Lengthen the measurement section.
If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
(1)Reset the alarm.
(2)Shorten the measurement section.
If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
(1)Reset the alarm.
(2)Increase the speed specification value of a measurement job or set
a small value for BASICV.
Or set a small value for BASICT, or lengthen the measurement section.
If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
(1)Reset the alarm.
(2)Set a large value for the BASICT, and then check again.
If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
(1)Check the following settings.
Check the settings for jobs.
If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).