Alarm Name
Alarm
Sub
Number
Code
4573
SPOT WELDER NO.
ERROR
4574
SPOT WELD
COMPLETE TIME
LIMIT
4575
ERROR IN WELD
START TIMING SET
4576
ERR IN MOTOR GUN
CONT MODE
4577
ERR IN MOTOR GUN
MODE RELEASE
4578
SPOT WELD ERROR
Meaning
Cause
other
Sub Code: Welder number
Setting error
other
Sub Code: Welder number
Setting error
other
Setting error
other
Software operation error
occurred
Software operation error
occurred
Sub Code: Welder number
Setting error
Remedy
If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
(1)Check the following settings.
Correct the welder number set in the gun characteristic file.
If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
(1)Check the following settings.
Turn ON the timer contactor power.
If the response from the timer takes too long time due to the system
layout, increase the timeout time.
If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
(1)Check the following settings.
Check the settings for the "WST" tag.
Check the settings for the pressure file.
If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance
mode, and then contact your Yaskawa representative about
occurrence status (operating procedure).
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance
mode, and then contact your Yaskawa representative about
occurrence status (operating procedure).
(1)Check the following settings.
Check the settings for the timer conductor where the welding error
occurred.