Alarm Name
Alarm
Sub
Number
Code
4800
WDT ERROR
(CONVERTER)
4822
HARD WIRE BASE
BLOCK ERROR
Meaning
Cause
other
Sub Code: Signifies the
Connection failure
physical No. of converter in
which the alarm occurred
Module failure (converter)
EAXA21 board failure
other
Sub Code: Signifies the
Connection failure
control axis number which
detected an error
Fuse failure
EAXA21 board failure
EAXB21 board failure
Remedy
If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
(1)Reset the alarm.
(2)If the alarm occurs again, check the connection and inserting state
of the following cables and connectors.
EAXA21-CN507,510
EAXB21-CN531,532,533
Converter CN551,553
EX1SV (External axis SERVO PACK)-CN591,592
(1)Reset the alarm.
(2)If the alarm occurs again, replace the converter.
(1)Reset the alarm.
(2)If the alarm occurs again, replace the EAXA21 board. Save the
CMOS.BIN before replacing the board to be safe.
If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
(1)Reset the alarm.
(2)If the alarm occurs again, check the connection and inserting state
of the following cables and connectors.
EAXA21 board CN521(Safety function's jumper connector)
EAXB21 board CN522/523/524(Safety function's jumper connector)
YSF22 board CN217
(1)Reset the alarm.
(2)If the alarm occurs again, check the connection of the fuse of
YSF22 board and then turn the power ON again.
(1)Reset the alarm.
(2)If the alarm occurs again, replace the EAXA21 board. Save the
CMOS.BIN before replacing the board to be safe.
(1)Reset the alarm.
(2)If the alarm occurs again, replace the EAXB21 board. Save the
CMOS.BIN before replacing the board to be safe.