Alarm Name
Alarm
Sub
Number
Code
6
7
8
4498
CANNOT EXECUTE
JOB (NO GRP AXIS)
4499
UNDEFINED
POSITION VARIABLE
Meaning
Cause
other
The 1st-axis rotation direction
Setting error
of C3, C4, and C5 of station
axes are not the same.
other
The 1st-axis (elevation axis)
Setting error
positions of C1, C2, and C3 of
station axes are not the same.
other
The 1st-axis (elevation axis)
Setting error
positions of C3, C4, and C5 of
station axes are not the same.
other
An attempt was made to
Setting error
execute an instruction that
could not be executed in a job
without control group.
other
Sub Code: The variable
Setting error
number
other
Remedy
If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
(1)Check the following settings.
Perform the teaching again so that the 1staxis rotation direction of C3,
C4, and C5 of station axes are the same.
If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
(1)Check the following settings.
Perform the teaching again so that the 1staxis (elevation axis)
positions of C1, C2, and C3 of station axes are the same.
If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
(1)Check the following settings.
Perform the teaching again so that the 1staxis (elevation axis)
positions of C3, C4, and C5 of station axes are the same.
If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
(1)Check the following settings.
Check the settings for the job instruction with control group.
If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
(1)Check the following settings.
Check the settings for the position type variable.
If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).