YASKAWA DX200 Maintenance Manual page 1035

Hide thumbs Also See for DX200:
Table of Contents

Advertisement

Alarm Name
Alarm
Sub
Number
Code
94
100
4596
FORMCUT ERROR
1
4597
OFFLINE POSITION
1
DATA CONVERT ERR
2
Meaning
Cause
Because the designated plane
Setting error
included reference points at
special circular interpolation
motion, the arc center
coordinates could not be
calculated. Incorrect teaching
of the reference point 2 may
be the cause.
other
The arc center position is not
Setting error
set for the special circular
interpolation motion.
other
An attempt was made to re-
Execute condition failure
execute the FORMCUT
instruction after interrupting it.
other
Incorrect information of
Software operation error
reference position data for
occurred
offline position data
conversion
Incorrect user-coordinate
Software operation error
number designation in the
occurred
standard position data for
offline position data
conversion
Remedy
(1)Check the following settings.
Setting of the reference point 2
If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
(1)Check the following settings.
Check the settings for the reference point 1 as the arc center position.
If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
(1)Check the following settings.
Re-execute the move instruction executed before the FORMCUT
instruction, and then execute the FORMCUT instruction again.
If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance
mode, and then contact your Yaskawa representative about
occurrence status (operating procedure).
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance
mode, and then contact your Yaskawa representative about
occurrence status (operating procedure).