Description and Action
Service
Request
Number
Description: Sensor indicates an abnormally high internal temperature. Action: Verify that:
A05-05x
1. The room ambient temperature is within the system operating environment.
2. There is unrestricted air flow around the system.
3. All system covers are closed.
4. There are no fan failures.
If none of these problems exist, then proceed with "MAP 1230: Linux Platform Error Problem
Resolution" on page 89.
Description: System shutdown due to abnormally high internal temperature. Action: Verify
that:
A05-06x
1. The room ambient temperature is within the system operating environment.
2. There is unrestricted air flow around the system.
3. All system covers are closed.
4. There are no fan failures.
If none of these problems exist, then proceed with "MAP 1230: Linux Platform Error Problem
Resolution" on page 89.
Description: Sensor indicates a power supply has failed. Action: Use "MAP 1230: Linux
Platform Error Problem Resolution" on page 89.
A05-07x
Description: System shutdown due to power supply failure. Action: Use "MAP 1230: Linux
Platform Error Problem Resolution" on page 89.
A05-08x
Description: Sensor detected a FRU that has failed. Action: Use "MAP 1230: Linux Platform
Error Problem Resolution" on page 89.
A05-09x
Description: System shutdown due to FRU that has failed. Action: Use "MAP 1230: Linux
Platform Error Problem Resolution" on page 89.
A05-10x
Description: System shutdown due to power fault with an unspecified cause. Action: Use
"MAP 1230: Linux Platform Error Problem Resolution" on page 89.
A05-14x
Description: System shutdown due to internal power supply failure. Action: Use "MAP 1230:
Linux Platform Error Problem Resolution" on page 89.
A05-16x
Description: System shutdown due to Fan failure. Action: Use "MAP 1230: Linux Platform
Error Problem Resolution" on page 89.
A05-19x
Description: System shutdown due to Over temperature condition. Action: Verify the
following:
A05-21x
v The room ambient temperature is within the system operating environment.
v There is unrestricted air flow around the system.
v All system covers are closed.
If all conditions are met, then use "MAP 1230: Linux Platform Error Problem Resolution" on
page 89.
A05-22x
Description: System shutdown due to over temperature and fan failure. Action: Use "MAP
1230: Linux Platform Error Problem Resolution" on page 89.
A05-24x
Description: Power Fault specifically due to internal battery failure. Action: Use "MAP 1230:
Linux Platform Error Problem Resolution" on page 89.
A0D-00x
Description: Error log analysis indicates an error detected by the Service Processor, but the
failure could not be isolated. Action: Use "MAP 1230: Linux Platform Error Problem
Resolution" on page 89.