Map 1420: Recovery Procedures For Hot-Pluggable Pci Adapters; Map 1421: Partition Will Not Boot Due To Faulty Adapter - IBM eserver p Series Service Manual

Hide thumbs Also See for eserver p Series:
Table of Contents

Advertisement

MAP 1420: Recovery Procedures for Hot-Pluggable PCI Adapters

This procedure is used to locate problems that might occur when performing a PCI adapter hot-plug
operation.
Find the symptom in the following table; then follow the instructions given in the Action column.
Symptom/Reference Code
Partition will not boot rendering PCI hot-plug manager
useless.
Partition boots, but PCI adapter is not recognized and
slot status is empty.

MAP 1421: Partition Will Not Boot Due to Faulty Adapter

Step 1421-1
The entire system must be shut down and powered off to repair.
Does the customer wish to restore the partition by isolating the faulty adapter without powering off
the entire system?
No
Go to "Step 1421-12" on page 115.
Yes
Go to "Step 1421-2."
Step 1421-2
At the HMC, view the resources assigned to the partition that will not boot.
Step 1421-3
Remove the faulty resource from the partition that will not boot. Record the slot location and the adapter
type.
Step 1421-4
Attempt to boot the partition.
Does the partition boot?
No
Go to "Step 1421-12" on page 115.
Yes
Go to "Step 1421-5."
Step 1421-5
Shut down the partition.
114
EserverpSeries 650 Service Guide
Recovery Procedures for Hot-Pluggable PCI Adapters
Action
Go to "MAP 1421: Partition Will Not Boot Due to Faulty
Adapter."
Go to "MAP 1422: Slot is Empty Even When Populated"
on page 115.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Eserver p650

Table of Contents