IBM eserver p Series Service Manual page 347

Hide thumbs Also See for eserver p Series:
Table of Contents

Advertisement

Table 6. Service Processor Error Codes. (continued)
Error Code Description
4067 0BF3 I/O hub 3, I/O port x (problem outside the
system unit
4067 0C10 Processor configuration error: VPD mismatch
for processor card 1
4067 0C11 Processor card 2 configuration error: VPD
mismatch for processor card 2
4067 0C12 Processor card 3 configuration error: VPD
mismatch for processor card 3
4067 0C13 Processor card 4 configuration error: VPD
mismatch for processor card 4
4067 0CA5 Invalid system configuration
4067 0CA6 No usable memory left in the system. The
system must be rebooted.
4067 0CA9 Processor memory configuration error
4067 0EA0 MOPS service processor code error.
4067 0EA1 Operating system code on main processor
4067 0EA2 PRD code on service processor error.
4067 0EA4 The service processor firmware detected a
hardware problem but was unable to isolate the
source.
4067 0EAF Service processor code and system type are
unknown
4067 0EB0 JTAG problem
4067 0EB1 Attention line 0 stuck fault
Action/
Possible Failing FRU
1. Check for system firmware updates.
2. Check the cabling between the RIO
interface card at U0.1-P1-H2.1 and the I/O
subsystems.
3. RIO connector extension card,
Location: U0.1-P1-H2.1
4. Call service support.
1. Check for system firmware updates.
2. Call service support.
1. Check for system firmware updates.
2. Call service support.
1. Check for system firmware updates.
2. Call service support.
1. Check for system firmware updates.
2. Call service support.
1. Check that the processor cards and
memory DIMMs are properly installed and
configured.
2. If there are any FRUs listed in the service
processor error log entry, replace them one
at a time.
3. Go to "MAP 1540: Problem Isolation
Procedures" on page 140.
Reboot in slow mode to isolate the failure.
Check plugging and configuration of DIMMs.
Reboot in slow mode.
1. Check for system firmware updates.
2. Call service support.
1. Check for operating system code updates.
2. Call service support.
1. Check for system firmware updates.
2. Call service support.
Call service support.
1. Check for system firmware updates.
2. Call service support.
Go to "MAP 1540: Problem Isolation
Procedures" on page 140.
Go to "MAP 1540: Problem Isolation
Procedures" on page 140.
Chapter 5. Error Code to FRU Index
327