Table 4. SPCN Error Codes for the processor subsystem (System Unit) (continued)
Error Code Description
1011 840A VPD +5 stuck high
1011 840B VPD access
1011 840C Memory DIMM misplug
1011 840D SPCN configuration
1011 840E SPCN default config
1011 840F Config ID not recognized
1011 8413 Invalid processor VPD
1011 8414 Invalid processor VPD
1011 8415 Invalid processor VPD
1011 8416 Invalid processor VPD
1011 8423 No processor VPD
1011 8424 No processor VPD
1011 8425 No processor VPD
1011 8426 No processor VPD
1011 8A00 The SPCN firmware has detected a change in
the drawer configuration
Action/
Possible Failing FRU
Go to "MAP 1540: Problem Isolation
Procedures" on page 140.
Go to "MAP 1540: Problem Isolation
Procedures" on page 140.
Verify that all of the memory DIMMs are
properly installed and seated.
1. Check SPCN cabling.
2. Set the I/O type. See Power Control
Network Utilities Menu on page 493.
3. Service processor/PCI backplane
Location: U0.1-P2
1. Check SPCN cabling.
2. Set the I/O type. See Power Control
Network Utilities Menu on page 493.
3. Service processor/PCI backplane
Location: U0.1-P2
1. Check SPCN cabling.
2. Set the I/O type. See Power Control
Network Utilities Menu on page 493.
3. Service processor/PCI backplane
Location: U0.1-P2
Processor card 1
Location: U0.1-P1-C1
Processor card 2
Location: U0.1-P1-C2
Processor card 3
Location: U0.1-P1-C3
Processor card 4
Location: U0.1-P1-C4
Processor card 1
Location: U0.1-P1-C1
Processor card 2
Location: U0.1-P1-C2
Processor card 3
Location: U0.1-P1-C3
Processor card 4
Location: U0.1-P1-C4
Informational message.