Table 6. Service Processor Error Codes. (continued)
Error Code Description
4069 0BF1 Problem with RIO interface (I/O slot 1, I/O hub
1)
4069 0BF2 Problem with RIO interface (I/O slot 2, I/O hub
2)
4069 0BF3 I/O hub 3, I/O port x (problem outside the
system unit
4069 0C10 Processor card 1 configuration error: VPD
mismatch for processor card 1
4069 0C11 Processor card 2 configuration error: VPD
mismatch for processor card 2
4069 0C12 Processor card 3 configuration error: VPD
mismatch for processor card 3
4069 0C13 Processor card 4 configuration error: VPD
mismatch for processor card 4
4069 0CA5 Invalid system configuration
4069 0CA6 No usable memory left in the system. The
system must be rebooted.
4069 0CA9 Processor memory configuration error
4069 0EA0 MOPS service processor code error.
346
EserverpSeries 650 Service Guide
Action/
Possible Failing FRU
1. Check for system firmware updates.
2. Check the cabling between the RIO
interface card at U0.1-P1-H1.1 and the I/O
subsystems.
3. RIO connector extension card,
Location: U0.1-P1-H1.1
4. Call service support.
1. Check for system firmware updates.
2. Check the cabling between the RIO
interface card at U0.1-P1-H2 and the I/O
subsystems.
3. RIO connector extension card,
Location: U0.1-P1-H2
4. Call service support.
1. Check for system firmware updates.
2. Check the cabling between the RIO
interface card at U0.1-P1-H2.1 and the I/O
subsystems.
3. RIO connector extension card,
Location: U0.1-P1-H2.1
4. Call service support.
1. Check for system firmware updates.
2. Call service support.
1. Check for system firmware updates.
2. Call service support.
1. Check for system firmware updates.
2. Call service support.
1. Check for system firmware updates.
2. Call service support.
1. Check that the processor cards and
memory DIMMs are properly installed and
configured.
2. If there are any FRUs listed in the service
processor error log entry, replace them one
at a time.
3. Go to "MAP 1540: Problem Isolation
Procedures" on page 140.
Reboot in slow mode to isolate the failure.
Check plugging and configuration of DIMMs.
Reboot in slow mode.
1. Check for system firmware updates.
2. Call service support.