Error Code Description
25A8 0xxx NVRAM problems
25A8 0000 Initialization failed, device test failed
25A8 0100 NVRAM data validation check failed.
25A8 0201 Unable to expand target partition - saving
configuration variable.
25A8 0202 Unable to expand target partition - writing error
log entry.
25A8 0203 Unable to expand target partition - writing VPD
data.
25A8 0210 Setenv/$Setenv parameter error - name
contains a null character.
25A8 0211 Setenv/$Setenv parameter error - value
contains a null character.
25A8 0215 NVRAM RIO-USR-select variable not found.
278
EserverpSeries 650 Service Guide
Action/
Possible Failing FRU
Errors reported against NVRAM can be caused
by low battery voltage and (more rarely) power
outages that occur during normal system
usage. With the exception of the 25A8 0000
error, these errors are warnings that the
NVRAM data content had to be reestablished
and do not require any FRU replacement
unless the error is persistent. When one of
these errors occurs, any system customization
(eg. boot device list) information has been lost,
the system may need to be re-configured.
If the error is persistent, replace the service
processor/PCI backplane,
Location: U0.1-P2
Refer to Action under error code
25A8 0xxx
Turn off, turn on system unit and retry the
operation before replacing any system
component.
Refer to Action under error code
25A8 0xxx
Refer to Action under error code
25A8 0xxx
Refer to Action under error code
25A8 0xxx
Refer to Action under error code
25A8 0xxx
Refer to Action under error code
25A8 0xxx
Refer to Action under error code
25A8 0xxx
1. Check for platform firmware updates. Apply
if available.
2. Call service support.