Table 5. SPCN Error Codes for I/O Subsystems (continued)
Error Code Description
1nn1 7610 Blower 1 fault (7311 Model D20 I/O Subsystem
only)
1nn1 7611 Blower 1 missing (7311 Model D20 I/O
Subsystem only)
1nn1 7620 Blower 2 fault (7311 Model D20 I/O Subsystem
only)
1nn1 7621 Blower 2 missing (7311 Model D20 I/O
Subsystem only)
1nn1 7630 Blower 3 fault (7311 Model D20 I/O Subsystem
only)
1nn1 7631 Blower 3 missing (7311 Model D20 I/O
Subsystem only)
1nn1 7640 Blower 4 fault (7311 Model D20 I/O Subsystem
only)
1nn1 7641 Blower 4 missing (7311 Model D20 I/O
Subsystem only)
1nn1 7650 Fan fault (7311 Model D10 I/O Subsystem only) 1. I/O subsystem backplane
1nn1 7651 Fan missing (7311 Model D10 I/O Subsystem
only)
1nn1 8400 Configuration ID conflict
1nn1 840D I/O type mismatch
Action/
Possible Failing FRU
Blower 1,
Location: U0.dd-F1
See the notices on page 255 for "dd" values.
Blower 1,
Location: U0.dd-F1
See the notices on page 255 for "dd" values.
Blower 2,
Location: U0.dd-F2
See the notices on page 255 for "dd" values.
Blower 2,
Location: U0.dd-F2
See the notices on page 255 for "dd" values.
Blower 3,
Location: U0.dd-F3
See the notices on page 255 for "dd" values.
Blower 3,
Location: U0.dd-F3
See the notices on page 255 for "dd" values.
Blower 4,
Location: U0.dd-F4
See the notices on page 255 for "dd" values.
Blower 4,
Location: U0.dd-F4
See the notices on page 255 for "dd" values.
Location: U0.dd-P1
2. Fan
Location: U0.dd-F5
See the notices on page 255 for "dd" values.
1. I/O subsystem backplane
Location: U0.dd-P1
2. Fan
Location: U0.dd-F5
See the notices on page 255 for "dd" values.
1. Check cabling
2. Set the I/O type. See Power Control
Network Utilities Menu on page 493.
3. I/O subsystem backplane
Location: U0.dd-P1
See the notices on page 255 for "dd" values.
1. Check cabling
2. Set the I/O type. See Power Control
Network Utilities Menu on page 493.
3. I/O subsystem backplane
Location: U0.dd-P1
See the notices on page 255 for "dd" values.
Chapter 5. Error Code to FRU Index
259