Step 1522-7
Replace the items in the following list one at a time. Turn off the power before removing the item, and turn
the power back on after replacing the item to determine if the drawer will power on.
1. Replace the power supply with the green DC good LED off solid.
2. Replace the other power supply with the one just removed from above.
3. Replace the I/O drawer backplane.
Does the I/O drawer power on?
No
Have all the items in the list above been replaced?
No
Go to beginning of this step and replace the next item.
Yes
Call service support.
The item just replaced was defective. This ends the procedure. Go to "MAP 0410: Repair
Yes
Checkout" in the Eserver pSeries Diagnostic Information for Multiple Bus Systems
Step 1522-8
Is this machine connected to dc power?
No
Go to "Step 1522-12" on page 129.
Yes
Go to "Step 1522-9."
Step 1522-9
Are all circuit breakers reset at the rack power distribution panel?
No
Reset the popped breaker by first turning off, then turning on.
This ends the procedure. Go to "MAP 0410: Repair Checkout" in the Eserver pSeries
Diagnostic Information for Multiple Bus Systems.
Yes
Go to "Step 1522-10."
Step 1522-10
Are all the dc power cables seated firmly and connected correctly from the rack power distribution
panel to the rack drawers?
No
Fix the connection.
This ends the procedure. Go to "MAP 0410: Repair Checkout" in the Eserver pSeries
Diagnostic Information for Multiple Bus Systems.
Yes
Go to "Step 1522-11" on page 129.
128
EserverpSeries 650 Service Guide