Honeywell Home VisionPRO 8000 Manual page 45

With redlink
Hide thumbs Also See for VisionPRO 8000:
Table of Contents

Advertisement

ISU
Installer Setup
Number
Name
50° F to 70° F
604
Remote Setback
Heat Setpoint
None
605
Drain Pan Alert
S1
S2
S3
S4
Normally Open
606
Drain Pan Alert is
Normally Closed
[See Settings]
None
607
Dirty Filter Alert
S1
S2
S3
S4
Normally Open
608
Dirty Filtr Alert is
Normally Closed
[See Settings]
None
609
Water Leak Alert
S1
S2
S3
S4
Table 3. Installer Setup (ISU) Table. (Continued)
Settings
Default
64° F
None
Normally Open
None
Normally Open
None
45
VISIONPRO
Residential,
Commercial
Requires
or Both
EIM
Commercial
Yes
Remote Setback requires an EIM (Equipment
Interface Module).
During occupied periods, the occupancy sensor
tells the thermostat to go to setback settings when
no one is in the room. If someone is in the room,
then it follows the settings of the occupied period.
The occupancy sensor is ignored during
unoccupied periods.
If the thermostat is setup for non-programmable,
the occupancy sensor tells the thermostat to go to
setback settings when no one is in the room. If
someone is in the room, then it follows the settings
set by the user.
Both
Yes
Dry Contact Alerts require an Equipment Interface
Module.
Select the terminals wired to the Full Drain Pan
Dry Contact Device.
Both
Yes
Dry Contact Alerts require an EIM (Equipment
Interface Module).
Choose an option appropriate for the type of
device installed.
Normally Open: The Dry Contact device is
normally open and will close when the device
detects the drain pan is full.
Normally Closed: The Dry Contact device is
normally closed and will open when the device
detects the drain pan is full.
Both
Yes
Dry Contact Alerts require an Equipment Interface
Module.
Select the terminals wired to the Dirty Filter Dry
Contact Device.
Both
Yes
Dry Contact Alerts require an EIM (Equipment
Interface Module).
Choose an option appropriate for the type of
device installed:
Normally Open: The Dry Contact device is
normally open and will close when the device
detects a dirty filter.
Normally Closed: The Dry Contact device is
normally closed and will open when the device
detects a dirty filter.
Both
Yes
Dry Contact Alerts require an Equipment Interface
Module.
Select the terminals wired to the Water Leak Dry
Contact Device (wet switch).
®
8000 WITH REDLINK™
Notes
68-0312—06

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Yth8321r1002Th8110r1008Th8321r1001Th8320r1003