Honeywell Home VisionPRO 8000 Manual page 54

With redlink
Hide thumbs Also See for VisionPRO 8000:
Table of Contents

Advertisement

®
VISIONPRO
8000 WITH REDLINK™
ISU
Installer Setup
Number
Name
Off
1013
High Outdoor Temp
Vent Lockout
80° F to 110° F (in 5° F
increments)
Off
1013
High Out. Dew Point
Vent Lockout
65° F to 85° F (in 5° F increments)
Yes
1014
Vent During Hum or
Dehum Calls
No
Off
1016
Vent On High
Indoor Humidity
On
Off
1017
Ventilator Core
Reminder
3, 6, 9, 12 Calendar Months
Off
1017
Ventilator Filter
3, 6, 9, 12 Calendar Months
Reminder
0, 1, 2
1100
Number of UV
Devices
Off, 6, 12, 24 Calendar Months
1105
UV Bulb 1 Reminder
Note: "1" is not
displayed if there is
only 1 UV Bulb
Off, 6, 12, 24 Calendar Months
1105
UV Bulb 2 Reminder
View / Edit Custom Reminders
1200
Custom Reminders
Add Custom Reminders
68-0312—06
Table 3. Installer Setup (ISU) Table. (Continued)
Settings
Default
Off
Off
Yes
On
Off
Off
0
Off
Off
None
Residential,
Commercial
Requires
or Both
EIM
Both
No
Both
No
Both
No
Both
No
Both
No
Both
No
Both
No
Both
No
Both
No
Both
No
54
Notes
Requires an outdoor sensor.
This ISU is only displayed when ISU 1000
Ventilation Type is set to ERV / HRV or Fresh Air
Damper.
See "Ventilation — Outdoor Condition Lockouts
(ISU 1013)" beginning on page 93.
Requires a Wireless Outdoor Sensor (sense
outdoor humidity).
This ISU is only displayed when ISU 1000
Ventilation Type is set to ERV / HRV or Fresh Air
Damper.
See "Ventilation — Outdoor Condition Lockouts
(ISU 1013)" beginning on page 93.
This feature is used to help reach the user's desired
humidity level by not allowing the ventilation
equipment to run during a call for humidification
or dehumidification.
Yes: Ventilation is allowed to run during a call for
humidification or dehumidification.
No: Ventilation is NOT allowed to run during a call
for humidification or dehumidification.
This ISU is only displayed when ISU 1000
Ventilation Type is set to ERV / HRV.
Off: The humidity level has no effect on
ventilation.
On: The thermostat removes excess humidity by
turning on the ventilator when the indoor humidity
rises 10% above the user's humidification setting.
The thermostat must be in the heat mode to
ventilate on high humidity.
Ventilator Core Cleaning Reminder
Ventilator Filter Cleaning Reminder
Press the up/down arrows to select the number of
UV devices installed in the system. Some systems
may have two UV devices, one for the A-Coil and
another for Air Treatment. A replacement reminder
can be setup for each one. Select 0 if no UV devices
are installed.
UV Bulb 1 Replacement Reminder
UV Bulb 2 Replacement Reminder
See "Customizable Reminders" beginning on
page 98.