ISU
Installer Setup
Number
Name
Off
312
Outdoor Lockout
5° F to 60° F (in 5° F increments)
Heat Pump
Off
312
Outdoor Lockout
Backup Heat
5° F to 65° F (in 5° F increments)
1 to 12 CPH
313
Radiant Cycles Per
Hour Stage 1
Note: "Stage 1" is
not displayed if
there is only 1 stage
of Radiant Heat.
1 to 12 CPH
313
Radiant Cycles Per
Hour Stage 2
Table 3. Installer Setup (ISU) Table. (Continued)
Settings
Default
Off
(See Notes)
Off
3
3
31
VISIONPRO
Residential,
Commercial
Requires
or Both
EIM
Both
No
ISU 312 Heat Pump Outdoor Lockout requires an
outdoor sensor.
Default is 40 F if ISU 201 Heating Equipment is
Air to Air Heat Pump and ISU 218 Backup Heat
Type is Gas/Oil.
Default is Off if ISU 201 Heating Equipment is Air
to Air Heat Pump and ISU 218 Backup Heat Type
is Electric.
Default is Off if ISU 201 Heating Equipment is
Geothermal or Geothermal Radiant.
Heat Pump Outdoor Lockout is optional for any
type of heat pump (Air to Air Heat Pump,
Geothermal Heat Pump or Geothermal Radiant
Heat).
See "Heat pump with outdoor temperature
lockouts" beginning on page 78.
Both
No
ISU 312 Backup Heat Outdoor Temperature
Lockout requires an outdoor sensor.
This ISU is only displayed if ISU 201 Heating
Equipment is Air to Air Heat Pump, Geothermal or
Geothermal Radiant and ISU 219 External fossil
fuel kit is set to No.
See "Heat pump with outdoor temperature
lockouts" beginning on page 78.
Both
No
This ISU is only displayed when ISU 201 Heating
Equipment is Geothermal Radiant.
The thermostat automatically defaults to the
recommended setting for Geothermal Radiant
Heat (3 CPH).
Cycle rate limits the maximum number of times
the system can cycle in a 1 hour period measured
at a 50% load. For example, when set to 3 CPH, at
a 50% load, the most the system will cycle is 3
times per hour (10 minutes on, 10 minutes off).
The system cycles less often when load conditions
are less than or greater than a 50% load.
Both
Yes
This ISU is only displayed when ISU 201 Heating
Equipment is Geothermal Radiant.
The thermostat automatically defaults to the
recommended setting for Geothermal Radiant
Heat (3 CPH).
Cycle rate limits the maximum number of times
the system can cycle in a 1 hour period measured
at a 50% load. For example, when set to 3 CPH, at
a 50% load, the most the system will cycle is 3
times per hour (10 minutes on, 10 minutes off).
The system cycles less often when load conditions
are less than or greater than a 50% load.
®