VISIONPRO
8000 WITH REDLINK™
The addition of the integral error is what differentiates the
thermostat from many other mechanical and electronic
thermostats. See Fig. 147.
PROPORTIONAL COOL
CONTROL POINT
P+I CONTROL
POINT
PROPORTIONAL HEAT
CONTROL POINT
THERMOSTAT
HEAT SETPOINT
HEATING
100
50
PERCENT LOAD
Fig. 147.

Installer Options

Installer options require a password and should only be
changed by a qualified technician.
Fig. 148.
Installer Options
Fig. 149.
Enter password
0
Fig. 150.

Using the Temperature Display

In some circumstances, the temperature displayed on the
Home screen may not match the temperature near the
thermostat.
68-0312—06
THERMOSTAT
COOL SETPOINT
P+I CONTROL POINT
COOLING
0
50
100
M4414
MCR34100
MCR33976
0 0 0
MCR33977
If your system is set up to use remote indoor sensors, it may
be reading a sensor in another location.
Temperature reading depends on location of sensor

Using the Humidity Display

In some circumstances, the humidity displayed on the
Home screen may not match humidity near the thermostat.
Some systems are set up to use two sensors, one to control
humidification, the other for dehumidification. These
sensors are often installed in different locations.
Depending on how your thermostat was installed, the
thermostat Home screen will display humidity readings
from only one sensor.
Humidity reading depends on location of sensor.
72
MCR33985
Fig. 151.
MCR3416
Fig. 152.