VISIONPRO
8000 WITH REDLINK™
ISU
Installer Setup
Number
Name
Off
408
Max. Cool Recovery
Outdoor Temp
-20° F to 100°F
No
409
Adaptive Recovery
Yes
50° F to 99° F
410
Minimum Cool
Setpoint
40° F to 90° F
410
Maximum Heat
Setpoint
Unlocked
411
Keypad Lockout
Partially Locked
Fully Locked
None
412
Residential:
Entry / Exit Remote
50° F to 99° F
- Home Cool
Setpoint
Note: setpoint is limited based on
setting at ISU 410.
Commercial:
Entry / Exit Remote
- Occupied Cool
Setpoint
68-0312—06
Table 3. Installer Setup (ISU) Table. (Continued)
Settings
Default
70° F
Yes
50° F
90° F
Unlocked
75° F
Residential,
Commercial
Requires
or Both
EIM
Commercial
No
Residential
No
Both
No
Both
No
Both
No
Both
No
40
Notes
Off: The cooling system will begin recovery at the
time that is scheduled.
When a Maximum Recovery Ramp Rate is set, the
thermostat will begin recovery early to ensure the
temperature is reached at the scheduled time.
Set a Maximum Recovery Ramp Rate based on the
rate that the cooling system can recover at for a
mild day in your region. Default setting is 6° F /
hour.
Set an Outdoor Temperature that is representative
of a mild day in your region to be associated with
the Maximum Recovery Ramp Rate.
The thermostat will begin recovery at the optimal
time based on a calculated ramp rate, allowing the
system to recover on time and save energy during
changing outdoor conditions.
During recovery, the setpoint changes at a rate in
degrees per hour depending on the outdoor
temperature.
No: The system will begin heating or cooling
recovery at the scheduled time.
Yes: The thermostat will begin heating or cooling
recovery early to ensure that the temperature is
reached at the scheduled time. The thermostat will
adjust the start time of the equipment based on
how quickly the scheduled temperature was
reached on previous days. See page 71 for more
information on Adaptive Intelligent Recovery.
The user cannot set the temperature below this
level.
The user cannot set the temperature above this
level.
Unlocked: User has access to all thermostat
settings.
Partially Locked: User can modify only
temperature settings.
Fully Locked: User cannot modify any settings.
The thermostat maintains this Cool setting when
the user presses Home / Occupied at the Entry /
Exit Remote. Select None to delete this
temperature setting. The thermostat only
responds to the Entry / Exit Remote if a
temperature is pre-set at this screen. See "Wireless
Entry/Exit Remote" beginning on page 111.