VISIONPRO
8000 WITH REDLINK™

ZONING

The following diagrams show the wiring for zoning with different IAQ equipment.
C R
1
VISIONPRO THERMOSTATS CAN BE POWERED BY ANY TRANSFORMER. IN THIS EXAMPLE THEY ARE POWERED BY
THE SAME TRANSFORMER THAT POWERS THE HZ432.
2
THERE CAN BE UP TO 4 VISIONPRO THERMOSTATS USED WITH A SINGLE THM4000R WIRELESS ADAPTER AND
HZ432 ZONE PANEL. THE THM4000R CANNOT BE USED IF THERE ARE MORE THAN 4 ZONES IN THE SYSTEM.
3
RH/RC JUMPER INSTALLED WHEN SINGLE HEAT/COOL TRANSFORMER IS USED.
4
DOTTED LINES APPLY ONLY TO MULTI-STAGE EQUIPMENT. SEE HZ432 INSTALLATION INSTRUCTIONS FOR
HEAT PUMP WIRING.
5
A THM4000R CANNOT BE USED WITH THE VISIONPRO THERMOSTAT IF THE THERMOSTAT IS CONTROLLING
HUMIDIFICATION, DEHUMIDIFICATION, OR VENTILATION.
Fig. 350. RedLINK VisionPRO thermostats with an HZ432 zone panel and no IAQ control.
68-0312—06
1
C R
C R
C
1
TRANSFORMER
C7735A1000
DATS
5
138
FURNACE
2
C
R
W
W2
C R
Y
Y2
G
4
R
THM4000R
POWER
WIRELESS SETUP
2
CONNECTED
CONNECT
THM4000R1000
M1
M4
M6
R
C
W1/E
W2
W3
Y1
Y2
G
O/B
L
RH
3
RC
W1/E
W2
W3
Y1
Y2
G
O
B
DS/BK
R
C
AZ1
AZ2
OT
OT
DATS
DATS
A
B
C
D
M34527B