Honeywell Home VisionPRO 8000 Manual page 87

With redlink
Hide thumbs Also See for VisionPRO 8000:
Table of Contents

Advertisement

2. Set Fan Control settings. See Fig. 204.
• On: Fan is always on.
• Automatic: Fan runs only when cooling system is
on.
• Circulate: Fan runs randomly, about 35% of the
time.
Fig. 204.
3. Set temperature and dehumidification settings. See
Fig. 205.
• Low Limit Temperature Setting
If the cooling system is used to control humidity
while Dehumidification Away Mode is active, the
thermostat allows the cooling system to lower the
indoor air to the Low Limit Temperature Setting to
reach the Dehumidification Setting at ISU 920.
• Temperature Setting
The temperature maintained while
Dehumidification Away Mode is active and the
desired humidity level is satisfied.
• Dehumidification Setting
The desired humidity level while Dehumidification
Away Mode is active.
87
®
VISIONPRO
8000 WITH REDLINK™
Fig. 205.
68-0312—06