VISIONPRO
8000 WITH REDLINK™
6. Set Dehumidifier Fan Control settings. See Fig. 199.
• Tstat Controls Fan
Thermostat turns on the dehumidifier and the fan
when dehumidification is needed.
• Equip Controls Fan
Thermostat turns on the dehumidifier when
dehumidification is needed. The fan is controlled
by the equipment.
Fig. 199.
7. Set the desired lockout option. See Fig. 200.
Fig. 200.
NOTE: ISU 1014 gives the option to lockout ventila-
tion during calls for dehumidification. This
helps maintain the desired humidity level.
Dehumidification Away Mode
Dehumidification Away Mode protects the home when
unoccupied for long periods of time during hot and humid
weather by maintaining the desired humidity and
temperature settings.
To start Dehumidification Away Mode, press MENU, then
select Dehum Away Mode.
68-0312—06
The thermostat automatically follows settings that are set
by the dealer during installer setup.
Press Cancel to end Dehumidification Away Mode.
Set up Dehumidification Away Mode
1. Select Allowed at ISU 918. See Fig. 203.
86
Fig. 201.
Fig. 202.
Fig. 203.