VISIONPRO
8000 WITH REDLINK™
ISU
Installer Setup
Number
Name
No
106
Outdoor Air Sensor
Yes
Conv. Forced Air
200
Heating System
Heat Pump
Radiant Heat
Other
None (Cool Only)
Heat Pump:
201
Heating Equipment
Air to Air Heat Pump
Geothermal
Geothermal Radiant
None
203
Radiant Stage 1
U1
U2
U3
None
204
Radiant Stage 2
U1
U2
U3
68-0312—06
Table 3. Installer Setup (ISU) Table. (Continued)
Settings
Default
No
Conv. Forced Air Both
Air to Air Heat
Pump
Default varies
based on
previous
selections
Default varies
based on
previous
selections
Residential,
Commercial
Requires
or Both
EIM
Both
No
No
Both
No
Both
No
Both
No
22
Notes
This ISU automatically defaults to Yes when a
Wireless Outdoor Sensor is connected.
An Outdoor Sensor is required to set the following
ISUs:
ISU 312 Outdoor Temperature Lockouts (Heat
Pump Lockout and Backup Heat Lockout)
ISU 405 Outdoor Temperature used with
Minimum Heat Recovery Ramp Rate
ISU 406 Outdoor Temperature used with
Maximum Heat Recovery Ramp Rate
ISU 407 Outdoor Temperature used with
Minimum Cool Recovery Ramp Rate
ISU 408 Outdoor Temperature used with
Maximum Cool Recovery Ramp Rate
ISU 805 Humidification - Window Protection
ISU 1013 Low Outdoor Temperature Ventilation
Lockout
ISU 1013 High Outdoor Temperature Ventilation
Lockout
ISU 1013 High Outdoor Dew Point Ventilation
Lockout (requires Wireless Outdoor Sensor)
This ISU is not displayed when ISU 200 Heating
System is set to Conv. Forced Air, Radiant Heat,
Other or None (Cool Only).
See "Geothermal Radiant Heat" beginning on
page 79.
This ISU is only displayed when ISU 201 Heating
Equipment is Geothermal Radiant.
Geothermal Radiant Heat must be wired to a U
terminal (U1, U2, or U3).
U1, U2 and U3 are normally open dry contacts
when configured for a stage of Heat. U1, U2 and
U3 require power from the system transformer or a
separate transformer.
U2 and U3 are only available on the Equipment
Interface Module (EIM).
This ISU is only displayed when ISU 201 Heating
Equipment is Geothermal Radiant.
Geothermal Radiant Heat must be wired to a U
terminal (U1, U2, or U3).
U1, U2 and U3 are normally open dry contacts
when configured for a stage of Heat. U1, U2 and
U3 require power from the system transformer or a
separate transformer.
U2 and U3 are only available on the Equipment
Interface Module (EIM).