Honeywell Home VisionPRO 8000 Manual page 35

With redlink
Hide thumbs Also See for VisionPRO 8000:
Table of Contents

Advertisement

ISU
Installer Setup
Number
Name
1 to 12 CPH
316
Backup Heat Cycles
Per Hour Stage 2
Off
324
Compressor Off
Time
1 - 5 minutes
0, 30, 60, 90 seconds, 2, 3, 4, 5,
326
Extended Fan Run
6, 7, 8, 9, 10, 11, 12, 13, 14, 15
Time in Cool
minutes
0, 30, 60, 90 seconds, 2, 3, 4, 5,
326
Extended Fan Run
6, 7, 8, 9, 10, 11, 12, 13, 14, 15
Time in Heat
minutes
2 or 4 periods per day
400
Scheduled Periods
Off
401
Pre-Occupancy
1 hour
Purge
2 hour
3 hour
Table 3. Installer Setup (ISU) Table. (Continued)
Settings
Default
Electric =
9 CPH
Gas / Oil =
5 CPH
5 minutes
0 seconds
0 seconds
4 periods per
day
Off
35
VISIONPRO
Residential,
Commercial
Requires
or Both
EIM
Both
No
This ISU is only displayed when ISU 207 or 213
Backup Heat Stages is set to 2 stages.
Cycle rate limits the maximum number of times
the system can cycle in a 1 hour period measured
at a 50% load. For example, when set to 3 CPH, at
a 50% load, the most the system will cycle is 3
times per hour (10 minutes on, 10 minutes off).
The system cycles less often when load conditions
are less than or greater than a 50% load. The
recommended cycle rate settings are below for
each heating equipment type:
Standard Efficiency Gas Forced Air = 5 CPH
High Efficiency Gas Forced Air = 3 CPH
Oil Forced Air = 5 CPH
Electric Forced Air = 9 CPH
Hot Water Fan Coil = 3 CPH
Hot Water Radiant Heat = 3 CPH
Geothermal Radiant Heat = 3 CPH
Steam = 1 CPH
Gravity = 1 CPH
Both
No
The thermostat has a built in compressor
protection (minimum off timer) that prevents the
compressor from restarting too early after a
shutdown. The minimum-off timer is activated
after the compressor turns off.
If there is a call during the minimum-off timer, the
thermostat shows "Wait" in the display.
Both
No
After the call for cooling ends, the thermostat
keeps the fan on for the selected amount of time
for increased efficiency. This may re-introduce
humidity into the living space.
Both
No
After the call for heating ends, the thermostat
keeps the fan on for the selected amount of time
for increased efficiency.
Both
No
Residential:
4 Periods = Wake, Leave, Return, Sleep
2 Periods = Wake, Sleep
Commercial:
4 Periods = Occupied 1, Unoccupied 1, Occupied
2, Unoccupied 2
2 Periods = Occupied 1, Unoccupied 1
Commercial
No
Runs the fan 1 to 3 hours before each occupied
period to provide a comfortable workplace upon
arrival.
®
8000 WITH REDLINK™
Notes
68-0312—06