Honeywell Home VisionPRO 8000 Manual page 82

With redlink
Hide thumbs Also See for VisionPRO 8000:
Table of Contents

Advertisement

®
VISIONPRO
8000 WITH REDLINK™
5. Select the system mode(s) to allow humidification.
See Fig. 181.
NOTE: Heat includes Heat, Emergency Heat and
Auto. If the system is in Auto mode, the ther-
mostat will allow humidification if the last
call was for heat.
Cool includes Cool and Auto. If the system is
in Auto mode, the thermostat will allow
humidification if the last call was for cool. A
discharge sensor is required to humidify in
the Cool mode. The thermostat prevents
condensation in the duct work by not allow-
ing the humidifier to run when the discharge
temperature goes below the dew point tem-
perature. The humidifier is allowed to run
again after the discharge temperature rises
above the dew point temperature.
Fig. 181.
6. Select from one of the Humidification Control
Options (ISU 807). See Fig. 182.
• Hum when Heat is On
The thermostat turns on the humidifier only if the
heat is currently running and humidification is
needed.
• Hum when Fan is On
The thermostat turns on the humidifier only if the
fan is currently running and humidification is
needed.
• Tstat Controls Fan
The thermostat turns on the humidifier and the
fan when humidification is needed.
• Hum Controls Fan
The thermostat turns on the humidifier when
humidification is needed and the humidifier
controls the fan.
68-0312—06
7. Set the desired lockout option. See Fig. 183.
NOTE: ISU 1014 gives the option to lockout ventila-
tion during calls for humidification. This
helps maintain the desired humidity level.
Control Humidification Level
1. Touch MENU and select Humidification.
Humidification
Window Protection
82
Fig. 182.
Fig. 183.
MCR34100
Fig. 184.
MCR34128
Fig. 185.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Yth8321r1002Th8110r1008Th8321r1001Th8320r1003

Table of Contents