VISIONPRO
8000 WITH REDLINK™
ISU
Installer Setup
Number
Name
Comfort
303
Cool Differential
Stage 2
1.0° F to 3.5° F from setpoint (in
0.5° F increments)
Comfort
303
Cool Differential
1.0°F - 4.0°F from setpoint (in
Stage 3
0.5° F increments)
Comfort
303
Cool Differential
Stage 4
1.0° F to 4.5° F from setpoint (in
0.5° F increments)
Comfort
304
Radiant Heat Diff.
Stage 2
1.0° F to 3.5° F from setpoint (in
0.5° F increments)
68-0312—06
Table 3. Installer Setup (ISU) Table. (Continued)
Settings
Default
Comfort
Comfort
Comfort
Comfort
Residential,
Commercial
Requires
or Both
EIM
Both
No
Commercial
No
Commercial
Yes
Both
No
28
Notes
ISU 301 Control Options must be set to Advanced
to view or adjust this ISU.
This ISU is only displayed when the thermostat is
set to 2 cool stages.
The indoor temperature must rise to the selected
differential setting before the thermostat turns on
the stage of cooling. For example, if stage 2 is set
to 2° F (1.0° C), the indoor temperature must be
2° F (1.0° C) away from the setpoint before stage 2
turns on. When set to Comfort, the thermostat uses
the stage of cooling as needed to keep the indoor
temperature within 1° F (0.5° C) degree of the
setpoint.
ISU 301 Control Options must be set to Advanced
to view or adjust this ISU.
This ISU is only displayed when the thermostat is
set to 3 cool stages.
The indoor temperature must rise to the selected
differential setting before the thermostat turns on
the stage of cooling. For example, if stage 3 is set
to 2° F (1.0° C), the indoor temperature must be
2° F (1.0° C) away from the setpoint before stage 3
turns on. When set to Comfort, the thermostat uses
the stage of cooling as needed to keep the indoor
temperature within 1° F (0.5° C) degree of the
setpoint.
ISU 301 Control Options must be set to Advanced
to view or adjust this ISU.
This ISU is only displayed when the thermostat is
set to 4 cool stages.
The indoor temperature must rise to the selected
differential setting before the thermostat turns on
the stage of cooling. For example, if stage 4 is set
to 2° F (1.0° C), the indoor temperature must be
2° F (1.0° C) away from the setpoint before stage 4
turns on. When set to Comfort, the thermostat uses
the stage of cooling as needed to keep the indoor
temperature within 1° F (0.5° C) degree of the
setpoint.
ISU 301 Control Options must be set to Advanced
to view or adjust this ISU.
This ISU is only displayed if ISU 201 Heating
Equipment is Geothermal Radiant and there are 2
radiant heat stages.
The indoor temperature must drop to the selected
differential setting before the thermostat will turn
on the stage of heating. For example, if stage 2 is
set to 2° F (1.0° C), the indoor temperature must
be 2° F (1.0° C) away from the setpoint before
stage 2 turns on. When set to Comfort, the
thermostat will use the stage of heating as needed
to keep the indoor temperature within 1° F (0.5°
C) degree of the setpoint.