Honeywell Home VisionPRO 8000 Manual page 48

With redlink
Hide thumbs Also See for VisionPRO 8000:
Table of Contents

Advertisement

®
VISIONPRO
8000 WITH REDLINK™
ISU
Installer Setup
Number
Name
Off
711
Air Filter 2
Reminder
Run Time:
10, 20, 30, 45, 60, 90, 120, 150
days
Calendar:
30, 45, 60, 75 days
3, 4, 5, 6, 9, 12, 15 months
Off
712
EAC Cell Reminder
Calendar Months:
6, 7, 8, 9, 10, 11, 12 months
Off
712
EAC Pre-Filter
Reminder
Calendar Months:
3, 4, 5, 6 months
Off
712
EAC Post Filter
Reminder
Calendar Months:
6, 7, 8, 9, 10, 11, 12 months
None
800
Humidifier Type
Steam
Bypass / Fan Pwrd
T-Stat Sensor
801
Sensor for Hum
Remote Indoor Sensor Name
Remote Indoor Sensor Name
Remote Indoor Sensor Name
Remote Indoor Sensor Name
Remote Indoor Sensor Name
Remote Indoor Sensor Name
(Up to 6 Remote Indoor Sensors)
None
803
Humidifier Wiring
U1
U2
U3
Off
805
Window Protection
On
68-0312—06
Table 3. Installer Setup (ISU) Table. (Continued)
Settings
Default
Off
Off
Off
Off
None
T-Stat Sensor
Thermostat
defaults to the
next unused U
terminal (U1,
U2, U3).
Off
Residential,
Commercial
Requires
or Both
EIM
Both
No
Both
No
Both
No
Both
No
Both
No
Both
No
Both
No
Both
No
48
Notes
Electronic Air Cleaner Cell Cleaning Reminder
Electronic Air Cleaner Pre-Filter Cleaning
Reminder
Electronic Air Cleaner Post-Filter Replacement
Reminder
Select a sensor to control humidification
(thermostat or an optional remote sensor). If
multiple sensors are installed, you can use a
different sensor for dehumidification control. See
"Humidification control" beginning on page 113.
Note: Humidity sensing cannot be averaged.
Number of Outputs:
TH8321 Thermostat: U1 terminals
Equipment Interface Module (EIM): U1, U2 and
U3 terminals
U1, U2, U3 are dry contacts that require power.
See "Wiring IAQ Equipment or a Heat/Cool Stage
to the U Terminals" beginning on page 130.
Requires an optional outdoor sensor.
Off: The thermostat controls the humidity level to
the user's desired humidity setting. Frost or
condensation may appear on windows.
On: The thermostat prevents frost or condensation
on windows by not allowing the humidifier to run
above a certain level. To prevent frost or
condensation, the thermostat may turn off the
humidifier before the humidity setting is reached.
See "Window Protection" beginning on page 80.