Honeywell Home VisionPRO 8000 Manual page 52

With redlink
Hide thumbs Also See for VisionPRO 8000:
Table of Contents

Advertisement

®
VISIONPRO
8000 WITH REDLINK™
ISU
Installer Setup
Number
Name
Automatic
919
Dehum Away Mode
Fan Setting
On
Circulate
70° F to 80° F
920
Dehum Away Mode
Low Limit Temp
70° F to 99° F
920
Dehum Away mode
Temp Setting
40% to 70% (in 5% increments)
920
Dehum Away mode
Dehum Setting
Off
921
Dehumidifier Filter
Reminder
30, 60, Calendar Days
3 to 12 Calendar Months (in 1
month increments)
None
1000
Ventilation Type
ERV / HRV
Passive (Fan Only)
Fresh Air Damper
None
1002
Ventilation Wiring
U1
U2
U3
ASHRAE
1005
Ventilation Method
Percent On Time
Tstat Controls Fan
1006
Vent Fan Control
Equip Controls Fan
1 to 6
1009
Number of
Bedrooms
68-0312—06
Table 3. Installer Setup (ISU) Table. (Continued)
Settings
Default
Automatic
76° F
85° F
65%
Off
None
Thermostat
defaults to the
next unused U
terminal (U1,
U2, U3).
Defaults to
ASHRAE
when ISU 101
Application is set
to Residential.
Percent on Time
is the only
choice when ISU
101 Application
is set to
Commercial.
Tstat Controls
Fan
2 bedrooms
Residential,
Commercial
Requires
or Both
EIM
Both
No
Both
No
Both
No
Both
No
Both
No
Both
No
Both
No
Both
No
Both
No
Residential
No
52
Notes
The On and Circulate settings may re-introduce
humidity into the living space.
If the cooling system is used to control humidity
while Dehumidification Away Mode is active, the
thermostat allows the cooling system to lower the
indoor air to the Low Limit Temperature Setting to
reach the dehumidification setting at ISU 920.
The temperature maintained while
Dehumidification Away Mode is active and the
desired humidity level is satisfied.
The desired humidity level while Dehumidification
Away Mode is active.
None: The thermostat does not control ventilation.
ERV/HRV: The thermostat controls an Energy
Recovery Ventilator or Heat Recovery Ventilator
for ventilation.
Passive (Fan Only): The thermostat turns on the
fan for ventilation.
Fresh Air Damper: The thermostat turns on the fan
and opens a fresh air damper for ventilation.
Number of Outputs:
TH8321 Thermostat: U1 terminals
Equipment Interface Module (EIM): U1, U2 and
U3 terminals
U1, U2, U3 are dry contacts that require power.
See "Wiring IAQ Equipment or a Heat/Cool Stage
to the U Terminals" beginning on page 130.
See "Ventilation Control Methods (ISU 1005)"
beginning on page 92.
Tstat Controls Fan: The thermostat turns on the
ventilation equipment and the fan when
ventilation is needed.
Equip Controls Fan: The thermostat turns on the
ventilation equipment when ventilation is needed.
The fan is controlled by the equipment.
This ISU is only displayed when ISU 1005
Ventilation Method is set to ASHRAE (Residential
only).