6.4.2 VENTILATION OF THE SPRAY BOOTH

The electrostatic spraying equipment may only be operated in defined spraying areas and
in accordance with the EN 12215 standard or under comparable ventilation conditions.
The electrostatic spraying equipment must be locked to the technical ventilation so that
the coating product supply and the high voltage are not effective as long as the technical
ventilation is not operated with the minimum exhaust air volume flow or a larger exhaust
air volume flow.
Ensure that the excess coating product (overspray) will be collected up safely.
WARNING
Toxic and/or flammable vapor mixtures!
Risk of poisoning and burns.
Operate the device in a spray booth approved for the working materials.
-or-
Operate the device on an appropriate spraying wall with the ventilation (extraction)
switched on.
Observe national and local regulations for the exhaust air speed.

6.4.3 PNEUMATIC CONNECTIONS

WARNING
Hose connections!
Risk of injury and damage to the device.
Do not mix up hose connections of product hose and air hose.
You must ensure that only dry, clean atomizing air is used in the spray gun. Dirt and
moisture in the atomizing air worsens the spraying quality and spray pattern.
For compressed air quality, see Chapter 5.5.1.
WARNING
Overpressure!
Risk of injury from bursting components.
The operating pressure must not exceed the value shown on the type plate.