Operating manual GA 5000EAC Electrostatic Automatic Spray Gun (AirCoat)
6   Assembly and Commissioning
6.4.3   Connecting the GA 5000EACEC Spray Gun
GA 5000
EPG 5000
Main Switch
Hauptschalter
I
0
Prim. Fuse
Sicherung
1.0 AT
Mains power IN
Netz Eingang
Spraygun
Sprühpistole
Umax. = 20Vpp
Imax. = 1.0A
1
For the product supply
2
Shaping air hose
3
Atomizing air hose
4
Control air hose
5
Gun cable
1. Place the control unit outside the explosion zone.
2. Mount spray gun to a grounded gun support.
3. Connect the grounding cable to the control unit and the signal ground.
4. Connect the gun connection cable to the control unit.
5. Connect the control unit to the higher-level controller (if available).
6. Connect the air hoses to the control unit and the spray gun in accordance with the
figure.
7. Set all airs to "0" using the regulator on the front side of the control unit!
8. Connect the control unit to the compressed air supply.
9. Connect the spray gun to the product supply system.
10. Connect the control unit to the power supply.
6.4.4   Ventilation of the Spray Booth
The electrostatic spraying equipment may only be operated in defined spraying areas and in
accordance with the EN 16985:2018 standard or under comparable ventilation conditions.
The electrostatic spraying equipment must be locked to the technical ventilation so that the
coating product supply and the high voltage are not effective as long as the technical
ventilation is not operated with the minimum exhaust air volume flow or a larger exhaust air
volume flow.
Ensure that the excess coating product (overspray) will be collected up safely.
Order number 2360922 | Edition 09/2022
2
3
5
4
Air input
Atomizing air
Lufteingang
Zerstäuberluft
IN
CAN Bus OUT
Data and Interlock
Daten und Verriegelung
Fan air
Control air
Formluft
CAN
Steuerluft
Address
Air input
6 - 8bar
Interface
87-116 psi
Schnittstelle
Clean and dry air
Saubere und trockene Luft
6.5.2 (ISO 8573-1:2010)
Service
Port
Restrictor for air during cleaning
Drossel für Luft während dem Spülen
B_05727
6
7
8
9
1
6
II (2) G
0102
SIRA 16 ATEX 5290X
Wagner International AG
Industriestrasse 22
CH - 9450 Altstätten
Made in Switzerland
Typ / Type:
EPG 5000
Artikel Nr.:
2359451
Article No.:
Serie Nr.:
Serial No.:
Baujahr:
Year of manufacture:
Spannung:
115VAC - 230VAC
Voltage:
50Hz / 60Hz
Eingangsleistung:
max. 40W
Input Power:
Eingangsstrom:
max. 0.5A
Input Current:
Schutzart:
IP 40
IP Code:
Norm:
EN 50176:2009
Standard:
EN 50050-1:2013
7
8
9
For the compressed air supply
Control cable
Grounding cable
Mains cable