D Source Drive Error Occurred; E Replacement Drive Capacity Too Small - 3Ware 9550SXU-12 User Manual

Sas/sata raid software raid controllers
Table of Contents

Advertisement

Troubleshooting

002D Source drive error occurred

002E Replacement drive capacity too small

280
Event Type
Error
Cause
An error on the source drive was detected during a rebuild operation. The
rebuild has stopped as a result.
Action
The controller will report an error, even if the area of the source drive that had
the error did not contain data. Scheduling regular verifies will lessen the
chance of getting this error.
You can force the rebuild to continue by setting the Overwrite ECC Error
policy through 3DM, CLI, or 3BM, and then rebuilding the unit again. This
will cause uncorrectable blocks to be rewritten, but the data may be incorrect.
It is recommended that you execute a file system check when the rebuild
completes.
Under Windows, right-click on your drive icon and choose
.
Tools> Check Now
Under Linux or FreeBSD use
SATA device, substitute the correct drive letter and partition number, such as
sdb2, for sda1.
See Also
"Starting a Verify Manually" on page 165
"Enabling or Disabling Auto Verify for a Unit" on page 120
"Setting Overwrite ECC (Continue on Source Error When Rebuilding)" on
page 121
Event Type
Error
Cause
The storage capacity of the drive you are using as a replacement drive is too
small and cannot be used.
3ware SAS/SATA RAID Software User Guide, Version 9.5.1