Enclosure Power Removed; Enclosure Power Added; Enclosure Power Unknown - 3Ware 9550SXU-12 User Manual

Sas/sata raid software raid controllers
Table of Contents

Advertisement

Troubleshooting

8032 Enclosure power removed

8033 Enclosure power added

8034 Enclosure power unknown

308
Action
Reseat the power supply cord. Replace any failed power supply as soon as
possible.
It is recommended to use an uninterruptible power supply (UPS) to protect
against power failures.
Event Type
Warning.
Cause
Applies only to the 9690SA controller.
One of the enclosure power supplies has been removed from the enclosure or
a power supply is unplugged.
Action
Return or reconnect the power supply as soon as possible.
It is recommended to use an uninterruptible power supply (UPS) to protect
against power failures.
Event Type
Information.
Cause
Applies only to the 9690SA controller.
A power supply has been added to the enclosure or an existing power supply
has been plugged in.
Action
None required.
Event Type
Warning.
3ware SAS/SATA RAID Software User Guide, Version 9.5.1

Hide quick links: