Exporting Jbod Disks - 3Ware 9550SXU-12 User Manual

Sas/sata raid software raid controllers
Table of Contents

Advertisement

Configuring Your Controller

Exporting JBOD Disks

96
It is possible to enable or disable automatic detection of drives on the controller's
ports for staggered spinup during hot swapping of drives. This feature is only
available in the CLI using the autodetect=on|off command. For more information,
see /cx set autodetect=on|off disk=<p:-p>|all 3ware SAS/SATA RAID Controller CLI
Guide.
Note:
Some hard drives require that the power management jumper (PM2) be set
to enable staggered spinup, in order for the SATA OOB option to be used. For more
information, see the knowledgebase article 14889, at
http://www.3ware.com/KB/article.aspx?id=14889
To enable or disable spinup and set the delay between spinups
1
At the main 3BM screen,
2
On the Policy
Control
choices you want to use:
Staggered Spinup:
Number of Drives Per Spinup:
depending on the number of ports on the controller.
Delay between spinup:
3
to the
button and press
Tab
OK
You will notice a short delay as 3BM makes the policy changes.
By default, JBOD disks (unconfigured disks) connected to the 3ware RAID
controller are not exported to the operating system. This means that any drives
you leave unconfigured are not seen by the operating system, and cannot be
used for storage. When Export JBOD Disks is set to No, you make individual
disks available for use by configuring them as Single Disks.
If you want unconfigured disks to be available on your computer, you can
change this setting in 3BM or CLI.
Note:
It is recommended that JBODs not be made available to the operating
system. The advantages of working with configured Single Disks over JBOD are:
If interrupted, a single disk media scan will continue from where it left off, while a
JBOD media scan must restart from the beginning.
Single disks can take advantage of the controller caching and the configuration is
persistent.
Single disks can be migrated to redundant units in the future (e.g. A single disk will
be able to be mirrored to another drive, creating a RAID 1 array).
3ware SAS/SATA RAID Software User Guide, Version 9.5.1
Tab
to
Policy
and press Enter.
screen,
through these fields, making the
Tab
Choose enabled or disabled.
Select the number of drives,
Select the number of seconds—from 1 to 6.
.
Enter

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

9690sa3ware 9650se

Table of Contents