3Ware 9550SXU-12 User Manual page 101

Sas/sata raid software raid controllers
Table of Contents

Advertisement

www.3ware.com
policies
Number of drives per spin-up
settings
. These policies can only be set using 3BM or the CLI.
Note:
This policy does not apply to drives attached to an expander.
Number of drives per spin-up.
the same time when the controller is powered up, if staggered spin-up
is enabled. From 1 to x, depending on the number of ports on the
controller.
Delay between spin-up.
groups that spin up at one time on this particular controller, if
staggered spin-up is enabled.
Delay before spin-up.
before the first set of drives on this particular controller will start to
spin-up.
It is possible to enable or disable automatic detection of drives on the
controller's ports for staggered spinup during hot swapping of drives. This
feature is only available in the CLI using the autodetect=on|off command.
For more information, see/cx set autodetect=on|off disk=<p:-
p>|all3ware SAS/SATA RAID Controller CLI Guide.
Export unconfigured disks (JBOD).
This setting indicates whether JBOD disks should be exported to the
operating system. JBOD configuration is strongly discouraged for newly
added disks on a 9000 series controller, in favor of Single Disk, so by
default, this setting is disabled. If you have a JBOD configuration from a
7000/8000 controller that you want to use on the 9000 series controller,
you should enable this setting. This policy can only be set in 3BM and
CLI.
Staggered method.
ATA-6 or SATA OOB (Out Of Band). By default, when Staggered Spin-
up is enabled, the OOB scheme is used. If your drives support the SATA
ATA-6 method, select that method in 3BM. There is no electronic method
for the controller to know if a drive supports this method, so it must be set
manually. For staggering to work properly, the drives must support the
selected method. This policy does not apply to drives that are attached to
an expander. This policy can only be set and only shows in 3BM.
Auto-Verify Preferred Date and Time.
auto-verify to run, when the Verify Schedule follows the weekly "Basic"
schedule and Auto-Verify is enabled for specific units. Note that in 3DM
the Basic and Advanced Auto Verify schedule is set on the
page. Enabling or Disabling Auto Verify is a Unit Policy and is set on the
Create Disk Array
3DM.
Some additional policies can be set at the unit level. For more information,
see "Setting Unit Policies" on page 116.
and
Number of drives that will spin up at
The delay time (in seconds) between drive
(3BM only) The delay time (in seconds)
This setting is disabled by default.
Indicates whether the type of staggered spin-up is
Sets the default date and time for
screen in 3BM and the
Controller Settings
About Controller Policies
Delay between spin-up
Schedule
page in
89