Spare Capacity Too Small; Migration Started; Migration Failed - 3Ware 9550SXU-12 User Manual

Sas/sata raid software raid controllers
Table of Contents

Advertisement

Troubleshooting

0032 Spare capacity too small

0033 Migration started

0034 Migration failed

282
See Also
For a list of compatible drives, see
http://www.3ware.com/products/compatibility_sata.asp
Event Type
Warning
Cause
There is a valid hot spare but the capacity is not sufficient to use it for a drive
replacement in existing units.
Action
Replace the spare with a drive of equal or larger capacity than the existing
drives.
Event Type
Information
Cause
The 3ware RAID controller has started the migration of a unit.
Migration changes can include:
Expanding capacity of a unit by adding drives
Changing RAID levels, for example, from RAID 1 to RAID 5
See Also
"RAID Level Migration (RLM) Overview" on page 128
Event Type
Error
3ware SAS/SATA RAID Software User Guide, Version 9.5.1