Troubleshooting
005F Cache synchronization failed; some data lost
0062 Enclosure removed
0063 Enclosure added
300
You will also see this message if drive insertion causes a unit to become
operational and retained write cache data was flushed.
Event Type
Error
Cause
The 3ware RAID controller performs cache synchronization when system
power is restored following a power failure. The cache synchronization was
not successful for some reason.
Event Type
Warning.
Cause
Applies only to the 9690SA controller.
An enclosure is no longer accessible to the 9690SA RAID controller. The
likely cause is that the enclosure has been powered down or that a cable has
been unplugged.
Event Type
Information.
Cause
Applies only to the 9690SA controller.
An enclosure is now accessible to the 9690SA RAID controller. The likely
cause is that an enclosure connected to the controller has been powered up or
that a cable has been plugged in.
3ware SAS/SATA RAID Software User Guide, Version 9.5.1