Verify Fixed Data/Parity Mismatch; So-Dimm Not Compatible; So-Dimm Not Detected - 3Ware 9550SXU-12 User Manual

Sas/sata raid software raid controllers
Table of Contents

Advertisement

Troubleshooting

0036 Verify fixed data/parity mismatch

0037 SO-DIMM not compatible

0038 SO-DIMM not detected

284
Event Type
Warning
Cause
A verify error was found and fixed by the 3ware RAID controller.
Some examples of errors that can be fixed include:
A parity inconsistency for a RAID 5 or RAID 50 unit.
A data mismatch for a RAID 1 or RAID 10 unit.
Action
None required.
Event Type
Error
Cause
There is incompatible SO-DIMM memory connected to the 9500S controller.
Note:
This message only applies to the 3ware 9500S controller, which has
removable memory. Other 3ware controller models do not have memory that
can be removed.
Action
Replace the incompatible SO-DIMM with a compatible one.
See Also
For a list of SODIMMs compatible with the 9500S, see
http://www.3ware.com/KB/article.aspx?id=11748.
Event Type
Error
3ware SAS/SATA RAID Software User Guide, Version 9.5.1