Figure 57. RAID Level Migration Example
Typically, a unit is reconfigured with the same or more storage capacity.
Sometimes additional drives are added. The following table shows valid
reconfigurations, some of which will require the addition of more drives.
Table 10: Valid Migration Paths
Source
R0
R1
Yes
No
R0
Yes
No
R1
Yes
No
R5
Yes
No
R6
Yes
No
R10
Yes
No
R50
Yes
Yes
Single
No
No
Spare
Note:
Rapid RAID Recovery will be disabled on any unit that is migrated.
Changing An Existing Configuration by Migrating
Destination
R5
R6
R10
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
No
No
R50
Single
Spare
Yes
No
No
Yes
Yes
No
Yes
No
No
Yes
No
No
Yes
No
No
Yes
No
No
Yes
No
No
No
No
No
129