Buffer Ecc Error Corrected; A Drive Power On Reset Detected - 3Ware 9550SXU-12 User Manual

Sas/sata raid software raid controllers
Table of Contents

Advertisement

0039 Buffer ECC error corrected

003A Drive power on reset detected

www.3ware.com
Cause
The 3ware 9500S RAID controller is inoperable due to missing SO-DIMM
memory.
This message only applies to the 3ware 9500S controller, which has
Note:
removable memory. Other 3ware controller models do not have memory that
can be removed.
Action
Install a compatible SO-DIMM on the controller.
See Also
For a list of SODIMMs compatible with the 9500S, see
http://www.3ware.com/KB/article.aspx?id=11748.
Event Type
Warning
Cause
The controller has detected and corrected a memory ECC error.
Action
None required.
If errors persist, contact technical support at
index.asp.
Event Type
Error
Cause
The controller has detected that a drive has lost power and then restarted. The
controller may degrade the unit if it is a redundant unit (non-redundant units
cannot be degraded).
Error and Notification Messages
http://www.3ware.com/support/