Unit Number Assignments Lost; Primary Dcb Read Error Occurred; Backup Dcb Read Error Detected - 3Ware 9550SXU-12 User Manual

Sas/sata raid software raid controllers
Table of Contents

Advertisement

0041 Unit number assignments lost

0042 Primary DCB read error occurred

0043 Backup DCB read error detected

www.3ware.com
Event Type
Warning
Cause
The unit number assignments have been lost.
This may have occurred as a result of a soft reset.
Action
Please contact AMCC 3ware technical support at
support/index.asp.
Event Type
Warning
Cause
The controller found an error while reading the primary copy of the Disk
Configuration Block (DCB).
The controller will attempt to correct the error by reading the back-up copy of
the DCB. If a valid DCB is found, the primary DCB is re-written to rectify the
errors.
Action
AMCC recommends verifying the unit. See "Starting a Verify Manually" on
page 165.
Event Type
Warning
Cause
The controller has detected a latent error in the backup Disk Configuration
Block (DCB).
Error and Notification Messages