Using Drive Capacity Efficiently - 3Ware 720-0192-00 Manual

Sas/sata raid controller
Table of Contents

Advertisement

Using Drive Capacity Efficiently

www.3ware.com
Table 3: Possible Configurations Based on Number of Drives
# Drives
Possible RAID Configurations
3
RAID 0
RAID 1 with hot spare
RAID 5
4
RAID 5 with hot spare
RAID 10
Combination of RAID 0, RAID 1, single disk
5
RAID 6
RAID 5 with hot spare
RAID 10 with hot spare
Combination of RAID 0, RAID 1, hot spare, single disk
6 or more
RAID 6
RAID 6 with hot spare
RAID 50
Combination of RAID 0, 1, 5, 6,10, hot spare, single disk
To make the most efficient use of drive capacity, it is advisable to use drives
of the same capacity in a unit. This is because the capacity of each drive is
limited to the capacity of the smallest drive in the unit.
The total unit capacity is defined as follows:
Table 4: Drive Capacity
RAID Level
Capacity
Single Disk
Capacity of the drive
RAID 0
(number of drives) X (capacity of the smallest drive)
RAID 1
Capacity of the smallest drive
RAID 5
(number of drives - 1) X (capacity of the smallest drive)
Storage efficiency increases with the number of disks:
storage efficiency = (number of drives -1)/(number of drives)
RAID 6
(number of drives - 2) x (capacity of the smallest drive)
RAID 10
(number of drives / 2) X (capacity of smallest drive)
RAID 50
(number of drives - number of groups of drives) X (capacity of the
smallest drive)
Understanding RAID Levels and Concepts