3Ware 9550SXU-12 User Manual page 238

Sas/sata raid software raid controllers
Table of Contents

Advertisement

3DM 2 Reference
226
Drive and choosing Properties; then on the Tools tab, click Check Now. Under
Linux or FreeBSD use the fsck utility command. For example,
sda1
.
Note:
The policy Overwrite ECC is equivalent to the "Continue on Source Error"
option in 3BM and the "IgnoreECC" option in the CLI.
(Not applicable for SAS drives) This policy enables or disables
Queuing.
Native Command Queuing (NCQ) for SATA drives in the unit. By default,
queuing is disabled. You can enable it, if desired.
NCQ only operates when the feature is enabled at both the drive and the
controller. If a drive does not support NCQ, the policy setting for the
controller is ignored.
Enabling NCQ can improve performance in many applications; it causes
command reordering to be done on the drive itself.
StorSave Profile.
The StorSave feature includes an option that lets you
change the StorSave Profile used for a unit. Three profiles are available:
Protection, Balanced, and Performance. These profiles automatically adjust
several different factors that affect protection and performance, including
whether FUA (Forced Unit Access) is honored, whether Write Journaling is
enabled, and whether Disable Cache on Degrade is enabled. For additional
information, see "Setting the StorSave Profile for a Unit" on page 123.
Note:
If the write cache setting is disabled for a unit, the StorSave Profile capability
does not apply and is automatically disabled.
Rapid RAID Recovery.
use,
,
or
All
Rebuild
Disable
unclean shutdowns.
Rebuild
between
All
and
Rebuild
disabled for the unit, it cannot be re-enabled. For additional information, see
"Rapid RAID Recovery" on page 126.
Unit Names
Units can be assigned names. A name can be assigned when the unit is created
and can be changed from this screen. For additional information, see "Naming
a Unit" on page 115.
3ware SAS/SATA RAID Software User Guide, Version 9.5.1
Determines which Rapid RAID Recovery option to
.
will apply the policy to both rebuilds and
All
will apply only to rebuilds. You can switch
settings. However, once Rapid RAID Recovery is
fsck /dev/

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

9690sa3ware 9650se

Table of Contents