B Verify Completed; C Source Drive Ecc Error Overwritten - 3Ware 9550SXU-12 User Manual

Sas/sata raid software raid controllers
Table of Contents

Advertisement

002B Verify completed

002C Source drive ECC error overwritten

www.3ware.com
place during off-hours. For more information, see "Scheduling Background
Tasks" on page 166. You can also set the initialization process to go slower
and use fewer system resources. For more information, see "Setting
Background Task Rate" on page 165. (Initialization occurs at the Rebuild
rate.)
See Also
"About Initialization" on page 158
Event Type
Information
Cause
Verification of the data integrity of a unit was completed successfully.
See Also
"About Verification" on page 162
Event Type
Error
Cause
A read error was encountered during a rebuild and the controller is configured
to 'ignore ECC' or to 'Force continue on source errors'. The sector in error
was reallocated.This will cause uncorrectable blocks to be rewritten, but the
data may be incorrect.
Action
It is recommended that you execute a file system check when the rebuild
completes.
Under Windows, right-click on your drive icon and choose
Tools> Check Now
.
Under Linux or FreeBSD use
SATA device, substitute the correct drive letter and partition number, such as
sdb2, for sda1.
Error and Notification Messages
fsck /dev/sda1
. If you have more than one
Properties>