B Rebuild Paused; C Initialize Paused - 3Ware 9550SXU-12 User Manual

Sas/sata raid software raid controllers
Table of Contents

Advertisement

Troubleshooting

003B Rebuild paused

003C Initialize paused

286
Action
If this drive was the only one to lose power, check the cable connections.
Also, check that your power supply is adequate for the type and number of
devices attached to it.
See Also
For troubleshooting information and a link to drive manufacturer diagnostic
utilities, see
http://www.3ware.com/KB/article.aspx?id=14927.
Event Type
Information
Cause
The rebuild operation is paused.
Rebuilds are normally paused for two (formerly ten) minutes after a system
first boots up and during non-scheduled times when scheduling is enabled.
Disabling or modifying the schedule with 3DM or CLI will allow the rebuild
to resume.
See Also
"Scheduling Background Tasks" on page 173
Event Type
Information
Cause
The initialization is paused.
Initializations are normally paused for two (formerly ten) minutes after a
system first boots up. Initialization is also paused during non-scheduled times
when scheduling is enabled. Initializations follow the rebuild schedule.
Action
If you want the initialize to resume, you can disable or modify the schedule
through 3DM or CLI.
3ware SAS/SATA RAID Software User Guide, Version 9.5.1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

9690sa3ware 9650se

Table of Contents