D Battery Temperature Is Too High; E Battery Capacity Test Started - 3Ware 9550SXU-12 User Manual

Sas/sata raid software raid controllers
Table of Contents

Advertisement

Troubleshooting

004D Battery temperature is too high

004E Battery capacity test started

294
Event Type
Error
Cause
The battery pack temperature being monitored by the Battery Backup Unit is
too high.
The BBU is unable to backup the 3ware RAID controller.
Action
Check for sufficient airflow around the card. To increase airflow you can:
Leave the PCI slots next to the controller empty
Add fans to your computer case
Move and bundle wiring that is blocking air circulation
Contact 3ware technical support at
if this problem is not due to environmental reasons or improper case cooling.
Event Type
Information
Cause
A battery test was started through CLI or 3DM.
Background Information
The test estimates how many hours the Battery Backup Unit will be able to
back up the 3ware RAID controller in case of a power failure.
This test performs a full battery charge/discharge/re-charge cycle and may
take up to 20 hours to complete. During this test the Battery Backup Unit
cannot backup the 3ware RAID controller. In addition, all units have their
write cache disabled until the test completes.
Action
None required.
3ware SAS/SATA RAID Software User Guide, Version 9.5.1
http://www.3ware.com/support/index.asp