E Initialize Failed; F Smart Threshold Exceeded - 3Ware 9550SXU-12 User Manual

Sas/sata raid software raid controllers
Table of Contents

Advertisement

Troubleshooting

000E Initialize failed

000F SMART threshold exceeded

270
Action
Allow the initialization to complete. This will return the unit to its normal
redundant state.
See Also
For more information, see "About Initialization" on page 158
Event Type
Error
Cause
The 3ware RAID controller was unable to complete the initialization. This
error can be caused by unrecoverable drive errors.
If this unit was a redundant unit, and the initialization failed because of a
problem on a particular disk drive, then the unit will be degraded.
Action
If the unit was degraded, then rebuild the unit. This may necessitate replacing
the drive.
Check physical cable and power connections. You can also run the drive
manufacturer's diagnostic and repair utilities on the drive.
See Also
For links to drive manufacturer diagnostic utilities and troubleshooting
advice, see
http://www.3ware.com/KB/article.aspx?id=10894
"Basic Troubleshooting: Check This First" on page 251
Event Type
Warning
Cause
SMART monitoring is predicting a potential drive failure.
The 3ware RAID controller supports SMART monitoring, whereby the
individual drives automatically monitor certain parametric information such
3ware SAS/SATA RAID Software User Guide, Version 9.5.1
.