(3) Press the [Management] key to enter management parameters interface;
(4) Move the cursor to 007 or 008 and select appropriate menu;
(5) Press the [EOB] key, the system confirms and performs backup and restore operation;
(6) The backup operation will generate the SYSCONF.BAK file in the root directory of disk D. Please save this file for
backup in the future.
(7) For restore operation, also save the SYSCONF.BAK file in the root directory of disk D. The system will recognize this
file automatically in the process of restoring.
10.5 Entering BISO Interface
(1) If the system can't be started due to irreversible error, you can enter the BIOS to upgrade and maintain the program;
(2) Enter the BIOS after the controller powers on and before the program is started, press the [Cancel] button to enter a blue
background successfully; if the BIOS has password, it will pop up a prompt, and type the valid password to enter the BIOS
(3) Enter the BIOS to perform the maintenance: Format C, D disk, copy USB disk files and upgrade;